| Ligne 3 : | Ligne 3 : | ||
'''Le 19/06/2025:''' | '''Le 19/06/2025:''' | ||
# Configuration pour compteurs Carlo Gavazzi EM340 triphasés | # Configuration pour compteurs Carlo Gavazzi EM340 triphasés | ||
# À ajouter dans configuration.yaml | # À ajouter dans configuration.yaml (ici, c'est la version qui marche) | ||
# Loads default set of integrations. Do not remove. | |||
default_config: | |||
# Load frontend themes from the themes folder | |||
frontend: | |||
themes: !include_dir_merge_named themes | |||
automation: !include automations.yaml | |||
script: !include scripts.yaml | |||
scene: !include scenes.yaml | |||
modbus: | |||
# Compteur EDF principal | |||
- name: "compteur_edf" | |||
type: tcp | |||
host: 192.168.1.252 | |||
port: 1485 | |||
timeout: 5 | |||
delay: 1 | |||
sensors: | |||
# === PUISSANCES ACTIVES (W) === | |||
- name: "EDF Puissance Active L1" | |||
slave: 1 | |||
address: 18 | |||
input_type: input | |||
data_type: int32 | |||
unit_of_measurement: "W" | |||
device_class: power | |||
state_class: measurement | |||
scan_interval: 5 | |||
scale: 0.1 | |||
swap: word | |||
- name: "EDF Puissance Active L2" | |||
slave: 1 | |||
address: 20 | |||
input_type: input | |||
data_type: int32 | |||
unit_of_measurement: "W" | |||
device_class: power | |||
state_class: measurement | |||
scan_interval: 5 | |||
scale: 0.1 | |||
swap: word | |||
- name: "EDF Puissance Active L3" | |||
slave: 1 | |||
address: 22 | |||
input_type: input | |||
data_type: int32 | |||
unit_of_measurement: "W" | |||
device_class: power | |||
state_class: measurement | |||
scan_interval: 5 | |||
scale: 0.1 | |||
swap: word | |||
- name: "EDF Puissance Active TOT+" | |||
slave: 1 | |||
address: 40 | |||
input_type: input | |||
data_type: int32 | |||
unit_of_measurement: "W" | |||
device_class: power | |||
state_class: measurement | |||
scan_interval: 5 | |||
scale: 0.1 | |||
swap: word | |||
- name: "EDF Energie kWh + L1" | |||
slave: 1 | |||
address: 64 | |||
input_type: input | |||
data_type: int32 | |||
unit_of_measurement: "kWh" | |||
device_class: power | |||
state_class: measurement | |||
scan_interval: 5 | |||
scale: 0.1 | |||
swap: word | |||
- name: "EDF Energie kWh + L2" | |||
slave: 1 | |||
address: 66 | |||
input_type: input | |||
data_type: int32 | |||
unit_of_measurement: "kWh" | |||
device_class: power | |||
state_class: measurement | |||
scan_interval: 5 | |||
scale: 0.1 | |||
swap: word | |||
- name: "EDF Energie kWh + L3" | |||
slave: 1 | |||
address: 68 | |||
input_type: input | |||
data_type: int32 | |||
unit_of_measurement: "kWh" | |||
device_class: power | |||
state_class: measurement | |||
scan_interval: 5 | |||
scale: 0.1 | |||
swap: word | |||
- name: "EDF Energie kWh + TOT" | |||
slave: 1 | |||
address: 52 | |||
input_type: input | |||
data_type: int32 | |||
unit_of_measurement: "kWh" | |||
device_class: power | |||
state_class: measurement | |||
scan_interval: 5 | |||
scale: 0.1 | |||
swap: word | |||
- name: "EDF Energie kWh - TOT" | |||
slave: 1 | |||
address: 78 | |||
input_type: input | |||
data_type: int32 | |||
unit_of_measurement: "kWh" | |||
device_class: power | |||
state_class: measurement | |||
scan_interval: 5 | |||
scale: 0.1 | |||
swap: word | |||
# Compteur Panneaux Solaires | |||
- name: "compteur_solaire" | |||
type: tcp | |||
host: 192.168.1.253 | |||
port: 2485 | |||
timeout: 5 | |||
delay: 1 | |||
sensors: | |||
# === PUISSANCES ACTIVES (W) === | |||
- name: "SOL Puissance Active L1" | |||
slave: 1 | |||
address: 18 | |||
input_type: input | |||
data_type: int32 | |||
unit_of_measurement: "W" | |||
device_class: power | |||
state_class: measurement | |||
scan_interval: 5 | |||
scale: 0.1 | |||
swap: word | |||
- name: "SOL Puissance Active L2" | |||
slave: 1 | |||
address: 20 | |||
input_type: input | |||
data_type: int32 | |||
unit_of_measurement: "W" | |||
device_class: power | |||
state_class: measurement | |||
scan_interval: 5 | |||
scale: 0.1 | |||
swap: word | |||
- name: "SOL Puissance Active L3" | |||
slave: 1 | |||
address: 22 | |||
input_type: input | |||
data_type: int32 | |||
unit_of_measurement: "W" | |||
device_class: power | |||
state_class: measurement | |||
scan_interval: 5 | |||
scale: 0.1 | |||
swap: word | |||
- name: "SOL Puissance Active TOT-" | |||
slave: 1 | |||
address: 40 | |||
input_type: input | |||
data_type: int32 | |||
unit_of_measurement: "W" | |||
device_class: power | |||
state_class: measurement | |||
scan_interval: 5 | |||
scale: 0.1 | |||
swap: word | |||
- name: "SOL Energie kWh + TOT" | |||
slave: 1 | |||
address: 52 | |||
input_type: input | |||
data_type: int32 | |||
unit_of_measurement: "kWh" | |||
device_class: power | |||
state_class: measurement | |||
scan_interval: 5 | |||
scale: 0.1 | |||
swap: word | |||
- name: "SOL Energie kWh - TOT" | |||
slave: 1 | |||
address: 78 | |||
input_type: input | |||
data_type: int32 | |||
unit_of_measurement: "kWh" | |||
device_class: power | |||
state_class: measurement | |||
scan_interval: 5 | |||
scale: 0.1 | |||
swap: word | |||
# === PUISSANCES ACTIVES (W) === | |||
- name: "SOL Puissance Active L1" | |||
slave: 1 | |||
address: 18 | |||
input_type: input | |||
data_type: int32 | |||
unit_of_measurement: "W" | |||
device_class: power | |||
state_class: measurement | |||
scan_interval: 5 | |||
scale: 0.1 | |||
swap: word | |||
- name: "SOL Puissance Active L2" | |||
slave: 1 | |||
address: 20 | |||
input_type: input | |||
data_type: int32 | |||
unit_of_measurement: "W" | |||
device_class: power | |||
state_class: measurement | |||
scan_interval: 5 | |||
scale: 0.1 | |||
swap: word | |||
- name: "SOL Puissance Active L3" | |||
slave: 1 | |||
address: 22 | |||
input_type: input | |||
data_type: int32 | |||
unit_of_measurement: "W" | |||
device_class: power | |||
state_class: measurement | |||
scan_interval: 5 | |||
scale: 0.1 | |||
swap: word | |||
- name: "SOL Puissance Active TOT-" | |||
slave: 1 | |||
address: 40 | |||
input_type: input | |||
data_type: int32 | |||
unit_of_measurement: "W" | |||
device_class: power | |||
state_class: measurement | |||
scan_interval: 5 | |||
scale: 0.1 | |||
swap: word | |||
- name: "SOL Energie kWh + TOT" | |||
slave: 1 | |||
address: 52 | |||
input_type: input | |||
data_type: int32 | |||
unit_of_measurement: "kWh" | |||
device_class: power | |||
state_class: measurement | |||
scan_interval: 5 | |||
scale: 0.1 | |||
swap: word | |||
- name: "SOL Energie kWh - TOT" | |||
slave: 1 | |||
address: 78 | |||
input_type: input | |||
data_type: int32 | |||
unit_of_measurement: "kWh" | |||
device_class: power | |||
state_class: measurement | |||
scan_interval: 5 | |||
scale: 0.1 | |||
swap: word | |||
ici, c'est la première version donnée par Claude, qui ne marche pas mais qui a des options intéressantes (à la fin) | |||
modbus: | modbus: | ||
Version du 19 juin 2025 à 14:02
KEYWORDS HOME ASSISTANT, HA, EM340
Le 19/06/2025:
- Configuration pour compteurs Carlo Gavazzi EM340 triphasés
- À ajouter dans configuration.yaml (ici, c'est la version qui marche)
- Loads default set of integrations. Do not remove.
default_config:
- Load frontend themes from the themes folder
frontend:
themes: !include_dir_merge_named themes
automation: !include automations.yaml script: !include scripts.yaml scene: !include scenes.yaml
modbus:
# Compteur EDF principal - name: "compteur_edf" type: tcp host: 192.168.1.252 port: 1485 timeout: 5 delay: 1 sensors:
# === PUISSANCES ACTIVES (W) ===
- name: "EDF Puissance Active L1"
slave: 1
address: 18
input_type: input
data_type: int32
unit_of_measurement: "W"
device_class: power
state_class: measurement
scan_interval: 5
scale: 0.1
swap: word
- name: "EDF Puissance Active L2"
slave: 1
address: 20
input_type: input
data_type: int32
unit_of_measurement: "W"
device_class: power
state_class: measurement
scan_interval: 5
scale: 0.1
swap: word
- name: "EDF Puissance Active L3"
slave: 1
address: 22
input_type: input
data_type: int32
unit_of_measurement: "W"
device_class: power
state_class: measurement
scan_interval: 5
scale: 0.1
swap: word
- name: "EDF Puissance Active TOT+"
slave: 1
address: 40
input_type: input
data_type: int32
unit_of_measurement: "W"
device_class: power
state_class: measurement
scan_interval: 5
scale: 0.1
swap: word
- name: "EDF Energie kWh + L1"
slave: 1
address: 64
input_type: input
data_type: int32
unit_of_measurement: "kWh"
device_class: power
state_class: measurement
scan_interval: 5
scale: 0.1
swap: word
- name: "EDF Energie kWh + L2"
slave: 1
address: 66
input_type: input
data_type: int32
unit_of_measurement: "kWh"
device_class: power
state_class: measurement
scan_interval: 5
scale: 0.1
swap: word
- name: "EDF Energie kWh + L3"
slave: 1
address: 68
input_type: input
data_type: int32
unit_of_measurement: "kWh"
device_class: power
state_class: measurement
scan_interval: 5
scale: 0.1
swap: word
- name: "EDF Energie kWh + TOT"
slave: 1
address: 52
input_type: input
data_type: int32
unit_of_measurement: "kWh"
device_class: power
state_class: measurement
scan_interval: 5
scale: 0.1
swap: word
- name: "EDF Energie kWh - TOT"
slave: 1
address: 78
input_type: input
data_type: int32
unit_of_measurement: "kWh"
device_class: power
state_class: measurement
scan_interval: 5
scale: 0.1
swap: word
# Compteur Panneaux Solaires - name: "compteur_solaire" type: tcp host: 192.168.1.253 port: 2485 timeout: 5 delay: 1 sensors:
# === PUISSANCES ACTIVES (W) ===
- name: "SOL Puissance Active L1"
slave: 1
address: 18
input_type: input
data_type: int32
unit_of_measurement: "W"
device_class: power
state_class: measurement
scan_interval: 5
scale: 0.1
swap: word
- name: "SOL Puissance Active L2"
slave: 1
address: 20
input_type: input
data_type: int32
unit_of_measurement: "W"
device_class: power
state_class: measurement
scan_interval: 5
scale: 0.1
swap: word
- name: "SOL Puissance Active L3"
slave: 1
address: 22
input_type: input
data_type: int32
unit_of_measurement: "W"
device_class: power
state_class: measurement
scan_interval: 5
scale: 0.1
swap: word
- name: "SOL Puissance Active TOT-"
slave: 1
address: 40
input_type: input
data_type: int32
unit_of_measurement: "W"
device_class: power
state_class: measurement
scan_interval: 5
scale: 0.1
swap: word
- name: "SOL Energie kWh + TOT"
slave: 1
address: 52
input_type: input
data_type: int32
unit_of_measurement: "kWh"
device_class: power
state_class: measurement
scan_interval: 5
scale: 0.1
swap: word
- name: "SOL Energie kWh - TOT"
slave: 1
address: 78
input_type: input
data_type: int32
unit_of_measurement: "kWh"
device_class: power
state_class: measurement
scan_interval: 5
scale: 0.1
swap: word
# === PUISSANCES ACTIVES (W) ===
- name: "SOL Puissance Active L1"
slave: 1
address: 18
input_type: input
data_type: int32
unit_of_measurement: "W"
device_class: power
state_class: measurement
scan_interval: 5
scale: 0.1
swap: word
- name: "SOL Puissance Active L2"
slave: 1
address: 20
input_type: input
data_type: int32
unit_of_measurement: "W"
device_class: power
state_class: measurement
scan_interval: 5
scale: 0.1
swap: word
- name: "SOL Puissance Active L3"
slave: 1
address: 22
input_type: input
data_type: int32
unit_of_measurement: "W"
device_class: power
state_class: measurement
scan_interval: 5
scale: 0.1
swap: word
- name: "SOL Puissance Active TOT-"
slave: 1
address: 40
input_type: input
data_type: int32
unit_of_measurement: "W"
device_class: power
state_class: measurement
scan_interval: 5
scale: 0.1
swap: word
- name: "SOL Energie kWh + TOT"
slave: 1
address: 52
input_type: input
data_type: int32
unit_of_measurement: "kWh"
device_class: power
state_class: measurement
scan_interval: 5
scale: 0.1
swap: word
- name: "SOL Energie kWh - TOT"
slave: 1
address: 78
input_type: input
data_type: int32
unit_of_measurement: "kWh"
device_class: power
state_class: measurement
scan_interval: 5
scale: 0.1
swap: word
ici, c'est la première version donnée par Claude, qui ne marche pas mais qui a des options intéressantes (à la fin)
modbus:
# Compteur EDF principal
- name: "compteur_edf"
type: tcp
host: 192.168.1.252
port: 1485
timeout: 5
delay: 1
sensors:
# === TENSIONS (V) ===
- name: "EDF Tension L1"
slave: 1
address: 0
input_type: input
data_type: uint16
unit_of_measurement: "V"
device_class: voltage
state_class: measurement
scale: 0.1
precision: 1
- name: "EDF Tension L2"
slave: 1
address: 2
input_type: input
data_type: uint16
unit_of_measurement: "V"
device_class: voltage
state_class: measurement
scale: 0.1
precision: 1
- name: "EDF Tension L3"
slave: 1
address: 4
input_type: input
data_type: uint16
unit_of_measurement: "V"
device_class: voltage
state_class: measurement
scale: 0.1
precision: 1
# === COURANTS (A) ===
- name: "EDF Courant L1"
slave: 1
address: 12
input_type: input
data_type: uint16
unit_of_measurement: "A"
device_class: current
state_class: measurement
scale: 0.001
precision: 3
- name: "EDF Courant L2"
slave: 1
address: 14
input_type: input
data_type: uint16
unit_of_measurement: "A"
device_class: current
state_class: measurement
scale: 0.001
precision: 3
- name: "EDF Courant L3"
slave: 1
address: 16
input_type: input
data_type: uint16
unit_of_measurement: "A"
device_class: current
state_class: measurement
scale: 0.001
precision: 3
# === PUISSANCES ACTIVES (W) ===
- name: "EDF Puissance Active L1"
slave: 1
address: 18
input_type: input
data_type: uint16
unit_of_measurement: "W"
device_class: power
state_class: measurement
- name: "EDF Puissance Active L2"
slave: 1
address: 19
input_type: input
data_type: uint16
unit_of_measurement: "W"
device_class: power
state_class: measurement
- name: "EDF Puissance Active L3"
slave: 1
address: 20
input_type: input
data_type: uint16
unit_of_measurement: "W"
device_class: power
state_class: measurement
- name: "EDF Puissance Active Totale"
slave: 1
address: 22
input_type: input
data_type: int32
unit_of_measurement: "W"
device_class: power
state_class: measurement
# === PUISSANCES RÉACTIVES (VAR) ===
- name: "EDF Puissance Réactive Totale"
slave: 1
address: 24
input_type: input
data_type: int32
unit_of_measurement: "var"
device_class: reactive_power
state_class: measurement
# === FACTEUR DE PUISSANCE ===
- name: "EDF Facteur Puissance L1"
slave: 1
address: 30
input_type: input
data_type: int16
unit_of_measurement: ""
state_class: measurement
scale: 0.001
precision: 3
- name: "EDF Facteur Puissance L2"
slave: 1
address: 31
input_type: input
data_type: int16
unit_of_measurement: ""
state_class: measurement
scale: 0.001
precision: 3
- name: "EDF Facteur Puissance L3"
slave: 1
address: 32
input_type: input
data_type: int16
unit_of_measurement: ""
state_class: measurement
scale: 0.001
precision: 3
# === ÉNERGIES (kWh) ===
- name: "EDF Énergie Active Importée"
slave: 1
address: 40
input_type: input
data_type: uint32
unit_of_measurement: "kWh"
device_class: energy
state_class: total_increasing
scale: 0.01
precision: 2
- name: "EDF Énergie Active Exportée"
slave: 1
address: 46
input_type: input
data_type: uint32
unit_of_measurement: "kWh"
device_class: energy
state_class: total_increasing
scale: 0.01
precision: 2
# === FRÉQUENCE ===
- name: "EDF Fréquence"
slave: 1
address: 70
input_type: input
data_type: uint16
unit_of_measurement: "Hz"
device_class: frequency
state_class: measurement
scale: 0.01
precision: 2
# Compteur Panneaux Solaires
- name: "compteur_solaire"
type: tcp
host: 192.168.1.253
port: 2485
timeout: 5
delay: 1
sensors:
# === TENSIONS (V) ===
- name: "Solaire Tension L1"
slave: 1
address: 0
input_type: input
data_type: uint16
unit_of_measurement: "V"
device_class: voltage
state_class: measurement
scale: 0.1
precision: 1
- name: "Solaire Tension L2"
slave: 1
address: 2
input_type: input
data_type: uint16
unit_of_measurement: "V"
device_class: voltage
state_class: measurement
scale: 0.1
precision: 1
- name: "Solaire Tension L3"
slave: 1
address: 4
input_type: input
data_type: uint16
unit_of_measurement: "V"
device_class: voltage
state_class: measurement
scale: 0.1
precision: 1
# === COURANTS (A) ===
- name: "Solaire Courant L1"
slave: 1
address: 12
input_type: input
data_type: uint16
unit_of_measurement: "A"
device_class: current
state_class: measurement
scale: 0.001
precision: 3
- name: "Solaire Courant L2"
slave: 1
address: 14
input_type: input
data_type: uint16
unit_of_measurement: "A"
device_class: current
state_class: measurement
scale: 0.001
precision: 3
- name: "Solaire Courant L3"
slave: 1
address: 16
input_type: input
data_type: uint16
unit_of_measurement: "A"
device_class: current
state_class: measurement
scale: 0.001
precision: 3
# === PUISSANCES ACTIVES (W) ===
- name: "Solaire Puissance Active L1"
slave: 1
address: 18
input_type: input
data_type: uint16
unit_of_measurement: "W"
device_class: power
state_class: measurement
- name: "Solaire Puissance Active L2"
slave: 1
address: 19
input_type: input
data_type: uint16
unit_of_measurement: "W"
device_class: power
state_class: measurement
- name: "Solaire Puissance Active L3"
slave: 1
address: 20
input_type: input
data_type: uint16
unit_of_measurement: "W"
device_class: power
state_class: measurement
- name: "Solaire Puissance Active Totale"
slave: 1
address: 22
input_type: input
data_type: int32
unit_of_measurement: "W"
device_class: power
state_class: measurement
# === PUISSANCES RÉACTIVES (VAR) ===
- name: "Solaire Puissance Réactive Totale"
slave: 1
address: 24
input_type: input
data_type: int32
unit_of_measurement: "var"
device_class: reactive_power
state_class: measurement
# === FACTEUR DE PUISSANCE ===
- name: "Solaire Facteur Puissance L1"
slave: 1
address: 30
input_type: input
data_type: int16
unit_of_measurement: ""
state_class: measurement
scale: 0.001
precision: 3
- name: "Solaire Facteur Puissance L2"
slave: 1
address: 31
input_type: input
data_type: int16
unit_of_measurement: ""
state_class: measurement
scale: 0.001
precision: 3
- name: "Solaire Facteur Puissance L3"
slave: 1
address: 32
input_type: input
data_type: int16
unit_of_measurement: ""
state_class: measurement
scale: 0.001
precision: 3
# === ÉNERGIES (kWh) ===
- name: "Solaire Énergie Active Importée"
slave: 1
address: 40
input_type: input
data_type: uint32
unit_of_measurement: "kWh"
device_class: energy
state_class: total_increasing
scale: 0.01
precision: 2
- name: "Solaire Énergie Active Exportée"
slave: 1
address: 46
input_type: input
data_type: uint32
unit_of_measurement: "kWh"
device_class: energy
state_class: total_increasing
scale: 0.01
precision: 2
# === FRÉQUENCE ===
- name: "Solaire Fréquence"
slave: 1
address: 70
input_type: input
data_type: uint16
unit_of_measurement: "Hz"
device_class: frequency
state_class: measurement
scale: 0.01
precision: 2
- === TEMPLATE SENSORS POUR CALCULS ===
template:
- sensor:
# Bilan énergétique
- name: "Bilan Puissance"
unit_of_measurement: "W"
device_class: power
state: "Modèle:(states('sensor.solaire puissance active totale')"
# Autoconsommation
- name: "Autoconsommation"
unit_of_measurement: "W"
device_class: power
state: >
{% set production = states('sensor.solaire_puissance_active_totale') | float(0) %}
{% set consommation = states('sensor.edf_puissance_active_totale') | float(0) %}
{% if production > 0 and consommation > 0 %}
{{ [production, consommation] | min }}
{% else %}
0
{% endif %}
# Injection réseau
- name: "Injection Réseau"
unit_of_measurement: "W"
device_class: power
state: >
{% set production = states('sensor.solaire_puissance_active_totale') | float(0) %}
{% set consommation = states('sensor.edf_puissance_active_totale') | float(0) %}
{% if production > consommation %}
Modèle:Production - consommation
{% else %}
0
{% endif %}
- === UTILITY METERS POUR SUIVI JOURNALIER/MENSUEL ===
utility_meter:
# Consommation EDF edf_energie_jour: source: sensor.edf_energie_active_importee cycle: daily edf_energie_mois: source: sensor.edf_energie_active_importee cycle: monthly # Production solaire solaire_production_jour: source: sensor.solaire_energie_active_exportee cycle: daily solaire_production_mois: source: sensor.solaire_energie_active_exportee cycle: monthly