« HA:: EM340 » : différence entre les versions
De wiki_pcwiki2
Aller à la navigationAller à la recherche
Aucun résumé des modifications |
Aucun résumé des modifications |
||
| Ligne 4 : | Ligne 4 : | ||
# Configuration pour compteurs Carlo Gavazzi EM340 triphasés | # Configuration pour compteurs Carlo Gavazzi EM340 triphasés | ||
# À ajouter dans configuration.yaml (ici, c'est la version qui marche) | # À ajouter dans configuration.yaml (ici, c'est la version qui marche) | ||
# Loads default set of integrations. Do not remove. | # Loads default set of integrations. Do not remove. | ||
| Ligne 15 : | Ligne 16 : | ||
script: !include scripts.yaml | script: !include scripts.yaml | ||
scene: !include scenes.yaml | scene: !include scenes.yaml | ||
# Configuration du recorder pour MariaDB | |||
recorder: | |||
db_url: mysql://homeassistant:fromspace@localhost/homeassistant?charset=utf8mb4 | |||
purge_keep_days: 365 # Garder 1 an d'historique | |||
commit_interval: 1 # Commit toutes les secondes pour les données temps réel | |||
auto_purge: true | |||
auto_repack: true | |||
# Inclure spécifiquement vos capteurs EM30 | |||
include: | |||
entities: | |||
# === COMPTEUR EDF === | |||
# Puissances actives | |||
- sensor.edf_puissance_active_l1 | |||
- sensor.edf_puissance_active_l2 | |||
- sensor.edf_puissance_active_l3 | |||
- sensor.edf_puissance_active_tot | |||
# Énergies EDF | |||
- sensor.edf_energie_kwh_l1 | |||
- sensor.edf_energie_kwh_l2 | |||
- sensor.edf_energie_kwh_l3 | |||
- sensor.edf_energie_kwh_tot | |||
- sensor.edf_energie_kwh_tot_2 # Le capteur "EDF Energie kWh - TOT" | |||
# === COMPTEUR SOLAIRE === | |||
# Puissances actives | |||
- sensor.sol_puissance_active_l1 | |||
- sensor.sol_puissance_active_l2 | |||
- sensor.sol_puissance_active_l3 | |||
- sensor.sol_puissance_active_tot | |||
# Énergies solaires | |||
- sensor.sol_energie_kwh_tot | |||
- sensor.sol_energie_kwh_tot_2 # Le capteur "SOL Energie kWh - TOT" | |||
# === CAPTEURS CALCULÉS (TEMPLATES) === | |||
- sensor.bilan_puissance | |||
- sensor.autoconsommation | |||
- sensor.injection_reseau | |||
# === UTILITY METERS === | |||
- sensor.edf_energie_jour | |||
- sensor.edf_energie_mois | |||
- sensor.sol_production_jour | |||
- sensor.sol_production_mois | |||
# Exclure les entités non essentielles pour économiser l'espace | |||
exclude: | |||
entity_globs: | |||
- sensor.*_battery* | |||
- sensor.*_signal* | |||
- binary_sensor.* | |||
domains: | |||
- automation | |||
- updater | |||
- sun | |||
- weather | |||
modbus: | modbus: | ||
| Ligne 81 : | Ligne 143 : | ||
data_type: int32 | data_type: int32 | ||
unit_of_measurement: "kWh" | unit_of_measurement: "kWh" | ||
device_class: | device_class: energy | ||
state_class: | state_class: total_increasing | ||
scan_interval: 5 | scan_interval: 5 | ||
scale: 0.1 | scale: 0.1 | ||
| Ligne 93 : | Ligne 155 : | ||
data_type: int32 | data_type: int32 | ||
unit_of_measurement: "kWh" | unit_of_measurement: "kWh" | ||
device_class: | device_class: energy | ||
state_class: | state_class: total_increasing | ||
scan_interval: 5 | scan_interval: 5 | ||
scale: 0.1 | scale: 0.1 | ||
| Ligne 105 : | Ligne 167 : | ||
data_type: int32 | data_type: int32 | ||
unit_of_measurement: "kWh" | unit_of_measurement: "kWh" | ||
device_class: | device_class: energy | ||
state_class: | state_class: total_increasing | ||
scan_interval: 5 | scan_interval: 5 | ||
scale: 0.1 | scale: 0.1 | ||
| Ligne 117 : | Ligne 179 : | ||
data_type: int32 | data_type: int32 | ||
unit_of_measurement: "kWh" | unit_of_measurement: "kWh" | ||
device_class: | device_class: energy | ||
state_class: | state_class: total_increasing | ||
scan_interval: 5 | scan_interval: 5 | ||
scale: 0.1 | scale: 0.1 | ||
| Ligne 129 : | Ligne 191 : | ||
data_type: int32 | data_type: int32 | ||
unit_of_measurement: "kWh" | unit_of_measurement: "kWh" | ||
device_class: | device_class: energy | ||
state_class: | state_class: total_increasing | ||
scan_interval: 5 | scan_interval: 5 | ||
scale: 0.1 | scale: 0.1 | ||
| Ligne 210 : | Ligne 272 : | ||
data_type: int32 | data_type: int32 | ||
unit_of_measurement: "kWh" | unit_of_measurement: "kWh" | ||
device_class: | device_class: energy | ||
state_class: | state_class: total_increasing | ||
scan_interval: 5 | scan_interval: 5 | ||
scale: 0.1 | scale: 0.1 | ||
| Ligne 222 : | Ligne 284 : | ||
data_type: int32 | data_type: int32 | ||
unit_of_measurement: "kWh" | unit_of_measurement: "kWh" | ||
device_class: | device_class: energy | ||
state_class: | state_class: total_increasing | ||
scan_interval: 5 | scan_interval: 5 | ||
scale: 0.1 | scale: 0.1 | ||
| Ligne 282 : | Ligne 344 : | ||
source: sensor.sol_energie_kwh_tot | source: sensor.sol_energie_kwh_tot | ||
cycle: monthly | cycle: monthly | ||
---------------------------------------------------------------------------------------------------------------------- | ---------------------------------------------------------------------------------------------------------------------- | ||
Dernière version du 19 juin 2025 à 15:30
KEYWORDS HOME ASSISTANT, HA, EM340
Le 19/06/2025:
- Configuration pour compteurs Carlo Gavazzi EM340 triphasés
- À ajouter dans configuration.yaml (ici, c'est la version qui marche)
- Loads default set of integrations. Do not remove.
default_config:
- Load frontend themes from the themes folder
frontend:
themes: !include_dir_merge_named themes
automation: !include automations.yaml script: !include scripts.yaml scene: !include scenes.yaml
- Configuration du recorder pour MariaDB
recorder:
db_url: mysql://homeassistant:fromspace@localhost/homeassistant?charset=utf8mb4
purge_keep_days: 365 # Garder 1 an d'historique
commit_interval: 1 # Commit toutes les secondes pour les données temps réel
auto_purge: true
auto_repack: true
# Inclure spécifiquement vos capteurs EM30
include:
entities:
# === COMPTEUR EDF ===
# Puissances actives
- sensor.edf_puissance_active_l1
- sensor.edf_puissance_active_l2
- sensor.edf_puissance_active_l3
- sensor.edf_puissance_active_tot
# Énergies EDF
- sensor.edf_energie_kwh_l1
- sensor.edf_energie_kwh_l2
- sensor.edf_energie_kwh_l3
- sensor.edf_energie_kwh_tot
- sensor.edf_energie_kwh_tot_2 # Le capteur "EDF Energie kWh - TOT"
# === COMPTEUR SOLAIRE ===
# Puissances actives
- sensor.sol_puissance_active_l1
- sensor.sol_puissance_active_l2
- sensor.sol_puissance_active_l3
- sensor.sol_puissance_active_tot
# Énergies solaires
- sensor.sol_energie_kwh_tot
- sensor.sol_energie_kwh_tot_2 # Le capteur "SOL Energie kWh - TOT"
# === CAPTEURS CALCULÉS (TEMPLATES) ===
- sensor.bilan_puissance
- sensor.autoconsommation
- sensor.injection_reseau
# === UTILITY METERS ===
- sensor.edf_energie_jour
- sensor.edf_energie_mois
- sensor.sol_production_jour
- sensor.sol_production_mois
# Exclure les entités non essentielles pour économiser l'espace
exclude:
entity_globs:
- sensor.*_battery*
- sensor.*_signal*
- binary_sensor.*
domains:
- automation
- updater
- sun
- weather
modbus:
# Compteur EDF principal - name: "compteur_edf" type: tcp host: 192.168.1.252 port: 1485 timeout: 5 delay: 1 sensors:
# === PUISSANCES ACTIVES (W) ===
- name: "EDF Puissance Active L1"
slave: 1
address: 18
input_type: input
data_type: int32
unit_of_measurement: "W"
device_class: power
state_class: measurement
scan_interval: 5
scale: 0.1
swap: word
- name: "EDF Puissance Active L2"
slave: 1
address: 20
input_type: input
data_type: int32
unit_of_measurement: "W"
device_class: power
state_class: measurement
scan_interval: 5
scale: 0.1
swap: word
- name: "EDF Puissance Active L3"
slave: 1
address: 22
input_type: input
data_type: int32
unit_of_measurement: "W"
device_class: power
state_class: measurement
scan_interval: 5
scale: 0.1
swap: word
- name: "EDF Puissance Active TOT+"
slave: 1
address: 40
input_type: input
data_type: int32
unit_of_measurement: "W"
device_class: power
state_class: measurement
scan_interval: 5
scale: 0.1
swap: word
- name: "EDF Energie kWh + L1"
slave: 1
address: 64
input_type: input
data_type: int32
unit_of_measurement: "kWh"
device_class: energy
state_class: total_increasing
scan_interval: 5
scale: 0.1
swap: word
- name: "EDF Energie kWh + L2"
slave: 1
address: 66
input_type: input
data_type: int32
unit_of_measurement: "kWh"
device_class: energy
state_class: total_increasing
scan_interval: 5
scale: 0.1
swap: word
- name: "EDF Energie kWh + L3"
slave: 1
address: 68
input_type: input
data_type: int32
unit_of_measurement: "kWh"
device_class: energy
state_class: total_increasing
scan_interval: 5
scale: 0.1
swap: word
- name: "EDF Energie kWh + TOT"
slave: 1
address: 52
input_type: input
data_type: int32
unit_of_measurement: "kWh"
device_class: energy
state_class: total_increasing
scan_interval: 5
scale: 0.1
swap: word
- name: "EDF Energie kWh - TOT"
slave: 1
address: 78
input_type: input
data_type: int32
unit_of_measurement: "kWh"
device_class: energy
state_class: total_increasing
scan_interval: 5
scale: 0.1
swap: word
# Compteur Panneaux Solaires - name: "compteur_solaire" type: tcp host: 192.168.1.253 port: 2485 timeout: 5 delay: 1 sensors:
# === PUISSANCES ACTIVES (W) ===
- name: "SOL Puissance Active L1"
slave: 1
address: 18
input_type: input
data_type: int32
unit_of_measurement: "W"
device_class: power
state_class: measurement
scan_interval: 5
scale: 0.1
swap: word
- name: "SOL Puissance Active L2"
slave: 1
address: 20
input_type: input
data_type: int32
unit_of_measurement: "W"
device_class: power
state_class: measurement
scan_interval: 5
scale: 0.1
swap: word
- name: "SOL Puissance Active L3"
slave: 1
address: 22
input_type: input
data_type: int32
unit_of_measurement: "W"
device_class: power
state_class: measurement
scan_interval: 5
scale: 0.1
swap: word
- name: "SOL Puissance Active TOT-"
slave: 1
address: 40
input_type: input
data_type: int32
unit_of_measurement: "W"
device_class: power
state_class: measurement
scan_interval: 5
scale: 0.1
swap: word
- name: "SOL Energie kWh + TOT"
slave: 1
address: 52
input_type: input
data_type: int32
unit_of_measurement: "kWh"
device_class: energy
state_class: total_increasing
scan_interval: 5
scale: 0.1
swap: word
- name: "SOL Energie kWh - TOT"
slave: 1
address: 78
input_type: input
data_type: int32
unit_of_measurement: "kWh"
device_class: energy
state_class: total_increasing
scan_interval: 5
scale: 0.1
swap: word
- === TEMPLATE SENSORS POUR CALCULS ===
template:
- sensor:
# Bilan énergétique
- name: "Bilan Puissance"
unit_of_measurement: "W"
device_class: power
state: "Modèle:(states('sensor.sol puissance active tot')"
# Autoconsommation
- name: "Autoconsommation"
unit_of_measurement: "W"
device_class: power
state: >
{% set production = states('sensor.sol_puissance_active_tot') | float(0) %}
{% set consommation = states('sensor.edf_puissance_active_tot') | float(0) %}
{% if production > 0 and consommation > 0 %}
{{ [production, consommation] | min }}
{% else %}
0
{% endif %}
# Injection réseau
- name: "Injection Réseau"
unit_of_measurement: "W"
device_class: power
state: >
{% set production = states('sensor.sol_puissance_active_tot') | float(0) %}
{% set consommation = states('sensor.edf_puissance_active_tot') | float(0) %}
{% if production > consommation %}
Modèle:Production - consommation
{% else %}
0
{% endif %}
- === UTILITY METERS POUR SUIVI JOURNALIER/MENSUEL ===
utility_meter:
# Consommation EDF edf_energie_jour: source: sensor.edf_energie_kwh_tot cycle: daily edf_energie_mois: source: sensor.edf_energie_kwh_tot cycle: monthly # Production sol sol_production_jour: source: sensor.sol_energie_kwh_tot cycle: daily sol_production_mois: source: sensor.sol_energie_kwh_tot cycle: monthly
ici, c'est la première version donnée par Claude, qui ne marche pas mais qui a des options intéressantes (à la fin)
modbus:
# Compteur EDF principal
- name: "compteur_edf"
type: tcp
host: 192.168.1.252
port: 1485
timeout: 5
delay: 1
sensors:
# === TENSIONS (V) ===
- name: "EDF Tension L1"
slave: 1
address: 0
input_type: input
data_type: uint16
unit_of_measurement: "V"
device_class: voltage
state_class: measurement
scale: 0.1
precision: 1
- name: "EDF Tension L2"
slave: 1
address: 2
input_type: input
data_type: uint16
unit_of_measurement: "V"
device_class: voltage
state_class: measurement
scale: 0.1
precision: 1
- name: "EDF Tension L3"
slave: 1
address: 4
input_type: input
data_type: uint16
unit_of_measurement: "V"
device_class: voltage
state_class: measurement
scale: 0.1
precision: 1
# === COURANTS (A) ===
- name: "EDF Courant L1"
slave: 1
address: 12
input_type: input
data_type: uint16
unit_of_measurement: "A"
device_class: current
state_class: measurement
scale: 0.001
precision: 3
- name: "EDF Courant L2"
slave: 1
address: 14
input_type: input
data_type: uint16
unit_of_measurement: "A"
device_class: current
state_class: measurement
scale: 0.001
precision: 3
- name: "EDF Courant L3"
slave: 1
address: 16
input_type: input
data_type: uint16
unit_of_measurement: "A"
device_class: current
state_class: measurement
scale: 0.001
precision: 3
# === PUISSANCES ACTIVES (W) ===
- name: "EDF Puissance Active L1"
slave: 1
address: 18
input_type: input
data_type: uint16
unit_of_measurement: "W"
device_class: power
state_class: measurement
- name: "EDF Puissance Active L2"
slave: 1
address: 19
input_type: input
data_type: uint16
unit_of_measurement: "W"
device_class: power
state_class: measurement
- name: "EDF Puissance Active L3"
slave: 1
address: 20
input_type: input
data_type: uint16
unit_of_measurement: "W"
device_class: power
state_class: measurement
- name: "EDF Puissance Active Totale"
slave: 1
address: 22
input_type: input
data_type: int32
unit_of_measurement: "W"
device_class: power
state_class: measurement
# === PUISSANCES RÉACTIVES (VAR) ===
- name: "EDF Puissance Réactive Totale"
slave: 1
address: 24
input_type: input
data_type: int32
unit_of_measurement: "var"
device_class: reactive_power
state_class: measurement
# === FACTEUR DE PUISSANCE ===
- name: "EDF Facteur Puissance L1"
slave: 1
address: 30
input_type: input
data_type: int16
unit_of_measurement: ""
state_class: measurement
scale: 0.001
precision: 3
- name: "EDF Facteur Puissance L2"
slave: 1
address: 31
input_type: input
data_type: int16
unit_of_measurement: ""
state_class: measurement
scale: 0.001
precision: 3
- name: "EDF Facteur Puissance L3"
slave: 1
address: 32
input_type: input
data_type: int16
unit_of_measurement: ""
state_class: measurement
scale: 0.001
precision: 3
# === ÉNERGIES (kWh) ===
- name: "EDF Énergie Active Importée"
slave: 1
address: 40
input_type: input
data_type: uint32
unit_of_measurement: "kWh"
device_class: energy
state_class: total_increasing
scale: 0.01
precision: 2
- name: "EDF Énergie Active Exportée"
slave: 1
address: 46
input_type: input
data_type: uint32
unit_of_measurement: "kWh"
device_class: energy
state_class: total_increasing
scale: 0.01
precision: 2
# === FRÉQUENCE ===
- name: "EDF Fréquence"
slave: 1
address: 70
input_type: input
data_type: uint16
unit_of_measurement: "Hz"
device_class: frequency
state_class: measurement
scale: 0.01
precision: 2
# Compteur Panneaux Solaires
- name: "compteur_solaire"
type: tcp
host: 192.168.1.253
port: 2485
timeout: 5
delay: 1
sensors:
# === TENSIONS (V) ===
- name: "Solaire Tension L1"
slave: 1
address: 0
input_type: input
data_type: uint16
unit_of_measurement: "V"
device_class: voltage
state_class: measurement
scale: 0.1
precision: 1
- name: "Solaire Tension L2"
slave: 1
address: 2
input_type: input
data_type: uint16
unit_of_measurement: "V"
device_class: voltage
state_class: measurement
scale: 0.1
precision: 1
- name: "Solaire Tension L3"
slave: 1
address: 4
input_type: input
data_type: uint16
unit_of_measurement: "V"
device_class: voltage
state_class: measurement
scale: 0.1
precision: 1
# === COURANTS (A) ===
- name: "Solaire Courant L1"
slave: 1
address: 12
input_type: input
data_type: uint16
unit_of_measurement: "A"
device_class: current
state_class: measurement
scale: 0.001
precision: 3
- name: "Solaire Courant L2"
slave: 1
address: 14
input_type: input
data_type: uint16
unit_of_measurement: "A"
device_class: current
state_class: measurement
scale: 0.001
precision: 3
- name: "Solaire Courant L3"
slave: 1
address: 16
input_type: input
data_type: uint16
unit_of_measurement: "A"
device_class: current
state_class: measurement
scale: 0.001
precision: 3
# === PUISSANCES ACTIVES (W) ===
- name: "Solaire Puissance Active L1"
slave: 1
address: 18
input_type: input
data_type: uint16
unit_of_measurement: "W"
device_class: power
state_class: measurement
- name: "Solaire Puissance Active L2"
slave: 1
address: 19
input_type: input
data_type: uint16
unit_of_measurement: "W"
device_class: power
state_class: measurement
- name: "Solaire Puissance Active L3"
slave: 1
address: 20
input_type: input
data_type: uint16
unit_of_measurement: "W"
device_class: power
state_class: measurement
- name: "Solaire Puissance Active Totale"
slave: 1
address: 22
input_type: input
data_type: int32
unit_of_measurement: "W"
device_class: power
state_class: measurement
# === PUISSANCES RÉACTIVES (VAR) ===
- name: "Solaire Puissance Réactive Totale"
slave: 1
address: 24
input_type: input
data_type: int32
unit_of_measurement: "var"
device_class: reactive_power
state_class: measurement
# === FACTEUR DE PUISSANCE ===
- name: "Solaire Facteur Puissance L1"
slave: 1
address: 30
input_type: input
data_type: int16
unit_of_measurement: ""
state_class: measurement
scale: 0.001
precision: 3
- name: "Solaire Facteur Puissance L2"
slave: 1
address: 31
input_type: input
data_type: int16
unit_of_measurement: ""
state_class: measurement
scale: 0.001
precision: 3
- name: "Solaire Facteur Puissance L3"
slave: 1
address: 32
input_type: input
data_type: int16
unit_of_measurement: ""
state_class: measurement
scale: 0.001
precision: 3
# === ÉNERGIES (kWh) ===
- name: "Solaire Énergie Active Importée"
slave: 1
address: 40
input_type: input
data_type: uint32
unit_of_measurement: "kWh"
device_class: energy
state_class: total_increasing
scale: 0.01
precision: 2
- name: "Solaire Énergie Active Exportée"
slave: 1
address: 46
input_type: input
data_type: uint32
unit_of_measurement: "kWh"
device_class: energy
state_class: total_increasing
scale: 0.01
precision: 2
# === FRÉQUENCE ===
- name: "Solaire Fréquence"
slave: 1
address: 70
input_type: input
data_type: uint16
unit_of_measurement: "Hz"
device_class: frequency
state_class: measurement
scale: 0.01
precision: 2
- === TEMPLATE SENSORS POUR CALCULS ===
template:
- sensor:
# Bilan énergétique
- name: "Bilan Puissance"
unit_of_measurement: "W"
device_class: power
state: "Modèle:(states('sensor.solaire puissance active totale')"
# Autoconsommation
- name: "Autoconsommation"
unit_of_measurement: "W"
device_class: power
state: >
{% set production = states('sensor.solaire_puissance_active_totale') | float(0) %}
{% set consommation = states('sensor.edf_puissance_active_totale') | float(0) %}
{% if production > 0 and consommation > 0 %}
{{ [production, consommation] | min }}
{% else %}
0
{% endif %}
# Injection réseau
- name: "Injection Réseau"
unit_of_measurement: "W"
device_class: power
state: >
{% set production = states('sensor.solaire_puissance_active_totale') | float(0) %}
{% set consommation = states('sensor.edf_puissance_active_totale') | float(0) %}
{% if production > consommation %}
Modèle:Production - consommation
{% else %}
0
{% endif %}
- === UTILITY METERS POUR SUIVI JOURNALIER/MENSUEL ===
utility_meter:
# Consommation EDF edf_energie_jour: source: sensor.edf_energie_active_importee cycle: daily edf_energie_mois: source: sensor.edf_energie_active_importee cycle: monthly # Production solaire solaire_production_jour: source: sensor.solaire_energie_active_exportee cycle: daily solaire_production_mois: source: sensor.solaire_energie_active_exportee cycle: monthly